1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m
BELOW THE UNIT.
General Data - Cooling Only
M5CCX010C M5CCX015C
M5LCX010C
M5LCX015C
Btu/h
9500 12000
W
2784 3517
W
830 1136
A
3.98 5.54
V/Ph/Hz
220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W
3.35 3.09
R410A R410A
OUTDOOR EXV OUTDOOR EXV
DUCTED DUCTED
SLM WIRED HANDSET SLM WIRED HANDSET
l/s / CFM
127 / 268 201 / 426
l/s / CFM
120 / 254 184 / 390
l/s / CFM
106 / 225 153 / 323
dBA
33 / 30 / 26 37 / 34 / 29
mm/in
261 / 10.28 261 / 10.28
mm/in
765 / 30.12 765 / 30.12
mm/in
411 / 16.18 411 / 1
6.18
mm/in
410 / 16.14 410 / 16.14
mm/in
951 / 37.44 951 / 37.44
mm/in
535 / 21.06 535 / 21.06
kg/lb
17 / 37.5 21 / 46.3
mm/in
19.05 / 3/4 19.05 / 3/4
l/s / CFM
378 / 800 425 / 900
dBA
47 52
mm/in
540 / 21.3 540 / 21.3
mm/in
700 / 27.6 700 / 27.6
mm/in
250 / 9.8 250 / 9.8
mm/in
601 / 23.7 601 / 23.7
mm/in
803 / 31.6 803 / 31.6
mm/in
320 / 12.6 320 / 12.6
kg/lb
38 / 83.6 38 / 83.6
FLARE VALVE FLARE VALVE
LIQUID mm/in
6.4 / 1/4 6.4 / 1/4
GAS mm/in
9
.5 / 3/8 12.7 / 1/2
kg/lb
0.90 / 1.87 0.90 / 1.98
WIDTH
DEPTH
UNIT DIMENSION
HEIGHT
AIR FLOW
PACKING DIMENSION WIDTH
DEPTH
UNIT DIMENSION
AIR FLOW
HEIGHT
UNIT WEIGHT
CONDENSATE DRAIN SIZE
REFRIGERANT CHARGE
Kommentare zu diesen Handbüchern