M5LCX-2009
CAUTION :
Drilling Holes And Mounting Plate Installation
Paste the installation plate provided on the desired location on the wall and marks the holes location
accordingly.
Ensure that the minimum maintenance and servicing space at the top, left and right side of the unit
is reserved.
Ensure also the levelness of the installation plate.
Drill the screw mounting holes (minimum 4 screws are required).
Drill the pipe hole at the location as per plan. (This is only applicable for rear piping outlet installation).
Note: The hole should be drilled slightly lower at outdoor side as per figure below:-
Fix the installation plate firmly to wall, without tilting to left or right. Use a plumb line, if available.
• Fixing methods:-
WOODEN
REINFORCED CONCRETE BUILDING
NUT ANCHOR
BOLT ANCHOR
If the condensing unit is operated in an atmosphere containing oils (including machine oils), salt (coastal
area), sulphide gas (near hot spring, oil refinery plant), such substances may lead to failure of the
unit.
If there is any obstacle higher than 2m, or if there is any obstruction at the upper part of the unit,
please allow more space than the figure indicated in the above table.
Indoor Side
Outdoor Side
72.0
'A'
'A'
Screw position in the wall
Dia 65.0mm Hole in the wall
Cautions:
i) Please check the unit weight for each model. Always ensure that the wall is sufficiently strong to
withstand the weight. If not, it is necessary to reinforce the wall with plate, beams or pillars.
ii) The unit cannot be directly fixed onto the wall or the likes. In all cases, the installation plate
provided MUST be used.