Electrical Data - Cooling Only (With Torque Control)
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
M5CMX015E
M5LCX015C
CLASS B
POWER SOURCE V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER W
79
RATED RUNNING CURRENT A
0.34
MOTOR OUTPUT W
26
4
CLASS B
POWER SOURCE V/Ph/Hz
220 - 240 / 1 / 50
RATED INPUT POWER W
71
RATED RUNNING CURRENT A
0.31
MOTOR OUTPUT W
35
6
CLASS E
POWER SOURCE V/Ph/Hz
0 - 300 / 3 / 0-100
CAPACITOR
µF
-
RATED INPUT POWER W
1130
RATED RUNNING CURRENT A
4.80
LOCKED ROTOR AMP. A
24
Electrical Data - Heat pump (With Torque Control)
M5CMX015ER
M5LCX015CR
CLASS B
POWER SOURCE
0 - 300 / 3 / 0-100
CAPACITOR
µF
-
RATED INPUT POWER (COOLING)
W
1130
RATED INPUT POWER (HEATING)
W
1000
RATED RUNNING CURRENT (COOLING)
A
4.80
RATED RUNNING CURRENT (HEATING)
A
4.50
LOCKED ROTOR AMP. A
24