1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m
BELOW THE UNIT.
M5WMX020GR M5WMX025GR
M5LCX020CR M5LCX025CR
Btu/h
18000 21000
W
5275 6155
Btu/h
19000 22000
W
5568 6448
W
1632 1991
W
1631 2013
A
7.90 11.30
A
8.00 11.80
V/Ph/Hz
220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W
3.23 3.09
W/W
3.41 3.20
R410A R410A
OUTDOOR EXV OUTDOOR EXV
l/s / CFM
260 / 550 297 / 630
l/s / CFM
208 / 440 236 / 500
l/s / CFM
175 / 370 198 / 420
dBA
44 / 40 / 35 49 / 43 / 40
mm/in
304 / 12 304 / 12
mm/in
1062 / 41.8 1062 / 41.8
mm/in
220 / 8.7
220 / 8.7
mm/in
378 / 14.9 378 / 14.9
mm/in
1130 / 44.5 1130 / 44.5
mm/in
292 / 11.5 270 / 10.6
kg/lb
15 / 33.1 15 / 33.1
mm/in
20 / 0.79 20 / 0.79
l/s / CFM
708 / 1500 755 / 1600
dBA
53 56
mm/in
757 / 6.67 757 / 6.67
mm/in
855 / 33.7 855 / 33.7
mm/in
328 / 12.9 328 / 12.9
mm/in
785 / 30.9 785 / 30.9
mm/in
983 / 38.7 983 / 38.7
mm/in
405 / 15.9 405 / 15.9
kg/lb
50 / 110.3 50 / 110.3
FLARE VALVE FLARE VALVE
LIQUID mm/in
6.4 / 1/4 6.4 / 1/4
GAS mm/
in
12.7 / 1/2 15.8 / 5/8
kg/lb
1.30 / 2.87 1.40 / 3.09
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
LOW
MEDIUM
INDOOR UNIT