General Data - Cooling Only (R410A)
68
M5CC 010C M5CC 015C
M5LC 010C M5LC 015C
Btu/h
9500 12500
W
2780 3660
W 961 1297
A
4.0 5.7
V/Ph/Hz
220 - 240 / 1 / 50 220 / 1 / 50
W/W 2.96 2.91
l/s / CFM
142 / 300 241 / 510
l/s / CFM
123 / 260 208 / 440
l/s / CFM 104 / 220 170 / 360
EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)
49 / 39 / 29 (0.2 / 0.2 / 0.1) 49 / 39 / 20 (0.2 / 0.2 / 0.1)
dBA
33 / 30 / 26 37 / 34 / 29
mm/in 261 / 10.3 261 / 10.3
mm/in
765 / 30.1 905 / 35.6
mm/in
411 / 16.2 411 / 16.2
mm/in 376 / 14.8 376 / 14.8
mm/in
951 / 37.4 1091 / 43.0
mm/in
541 / 21.3 541 / 21.3
kg/lb 17 / 38 21 / 46
mm/in
l/s / CFM
396 / 840 453 / 960
dBA
46 49
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
LIQUID mm/in
6.4 / 1/4 6.4 / 1/4
GAS mm/in 9.5 / 3/8 12.7 / 1/2
kg/lb
0.71 / 1.57 0.94 / 2.07
OUTDOOR CAP. TUBE
REFRIGERANT CONTROL (EXPANSION DEVICE)
EER
330 / 13.0
620 / 24.4
700 / 27.6
R410A
CONTROL
AIR DISCHARGE
OPERATION
FLARE VALVE
INDOOR UNIT
DUCTED
SLM WIRED HANDSET
19.1 / 3/4
UNIT DIMENSION
32 / 71
810 / 31.9
250 / 9.8
540 / 21.3
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
WEIGHT
MODEL
OUTDOOR UNIT
LOW
INDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE
REFRIGERANT TYPE
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
DEPTH
HIGH
MEDIUM
UNIT DIMENSION
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
SOUND PRESSURE LEVEL
CONDENSATE DRAIN SIZE
OUTDOOR UNIT
REFRIGERANT CHARGE
AIR FLOW
DEPTH
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.
Kommentare zu diesen Handbüchern