Catalog 1300-1 / Page 30 of 42
Accessories Common to 16" × 42" Units
Hydronic Subbase 8" High Heat Section
The PDAC hydronic model requires 1" minimum
from the front edge of the wall sleeve to the
nished wall. Side channels are furnished with all
subbases for a maximum depth extension of 13¾".
Subbases are available with or without receptacles
or fuse disconnect switches
2-row, nned/tube coil furnished for either hot
water or steam and mounted in an 8" subbase. 5/8"
O.D. copper pipe connections supplied. Louvered
subbase front panel with quick opening latches is
hinged for easy access to piping, valves and 1/2"
permanent lter.
3/4"
Receptacle (Factory installed when
fuse & disconnect are furnished)
As Req’d
Notes:
1. Side channels are adjustable from 0" – 9
3
/8" in length
by inverting them. Side channels are pre drilled to allow
innite adjustment.
2. Subbase shown with louvered front panel removed. Front
panel is hinged to allow access to valve, coil, lter &
electrical junction box.
3. Leveling legs are adjustable from 1/4" – 1
1
/4".
2
1
/2"
8
1
/4"
2
1
/2"
1
1
/2"
1/4" – 1
1
/4"
8"
3
1
/4"
5
1
/2"
7
1
/2"
6
3
/4"
7
1
/4"
3/4"
41
1
/2"
15"
Fuses
5/8" O.D. Copper Sweat
3" x 5" Opening for Electrical
and/or Piping Rough-in
Optional Disconnect
Permanent
Mesh Filter
Electrical
Knockout
Top View
Front View
End View
Leveling Legs
Hydronic Subbase – Weight
8" (203mm) High Hydronic ................20 lbs. (9 kg)