McQuay MMC Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Split-System-Klimaanlagen McQuay MMC herunter. McQuay MMC Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1

Catalog 2110BCeiling Ceiling And Floor ConvertibleAnd Floor ConvertibleFan Coil UnitFan Coil UnitModels: MCM 020D/DRMCM 025D/DRMCM 030D/DRMCM 040D/DRM

Seite 2 - ContentsContents

9Model: MCM 030D - MLC 030C

Seite 3

10Model: MCM 030D - MMC 030A

Seite 4 - Specifications

11Model : MCM 040D/050D - MLC 040C/050C

Seite 5 - Heat Pump

12Model: MCM 040D - MMC 040B

Seite 6 - (Cooling only and heat pump)

13Model: MCM 050D - MMC 050B

Seite 7 - Model: MMC SERIES

14Model: MCM 020DR - MLC 020BRMCM 025DR - MLC 025BR

Seite 8

15Model: MCM 030DR - MLC 030CR

Seite 9

16Model: MCM 040DR - MLC 040CRMCM 050DR - MLC 050CR

Seite 10 - Model: MCM 030D - MLC 030C

17InstallationCautionSharp edges and coil surface are potential injury hazard. Avoid from contact with them.(1) INSTALLATION OF INDOOR UNITPreliminary

Seite 11 - Model: MCM 030D - MMC 030A

18Please ensure that the following steps are taken:• Cheek the gradient for drainage flow as recommended in Figure B.• Provide clearance for easy serv

Seite 12

1ContentsContentsSpecial Features ... 2S

Seite 13 - Model: MCM 040D - MMC 040B

19Installation - Ceiling Exposed TypeSTEP 1Remove air intake grille, side panel, side close-up and hanger bracket from the unit; see Fig E.Figure ESTE

Seite 14 - Model: MCM 050D - MMC 050B

20Installation - Floor Standing TypeSTEP 1Remove air intake grille, side panel, side close-up and side panel from the unit; see Fig E.STEP 2Position t

Seite 15 - MCM 025DR - MLC 025BR

21(2) Installation Of Outdoor UnitAs condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achievemaximu

Seite 16 - Model: MCM 030DR - MLC 030CR

22MMC SERIESALL MODELS A B CMinimum Distance 300mm 1000mm 300mm(3) Refrigerant PipingMaximum Pipe Length And Maximum Number Of Bends• When the pipe le

Seite 17 - MCM 050DR - MLC 050CR

23(4) WiringElectrical Connections• Wiring regulations on wire diameters differ from country to country. Please refer to your LOCALELECTRICAL CODES fo

Seite 18 - Installation

24(6) Additional Charge• The refrigerant gas has already charged into the outdoor unit. For the piping length of 5m. Additional refrigerantcharge afte

Seite 19 - Semi-Enclose Mounting

25(8) Standard Operating ConditionCooling Only UnitTemperature Ts °CTh °Cminimum indoor temperature19.4 13.9maximum indoor temperature26.7 19.4minimum

Seite 20

26Servicing and maintenanceWarningDisconnect from Main Supply before Servicing the air conditionerThe unit is designed to give a long life operation w

Seite 21

27The design of the MLC outdoor series allows servicing to be carried out readily and easily. The removal of thetop side, front and back panel make al

Seite 22 - Installation Clearance

28TroubleshootingWhen any air-conditioner malfunction is noted, immediately switch off the power supply to the unit, andcontact the local dealer, if n

Seite 23 - (3) Refrigerant Piping

2Special featuresSpecial featuresUltra Slim New Stylish Design ProfileThis unit is contemporary in design and match even the most up to date interior

Seite 24 - (5) Vacuuming and Charging

29Diagnosis By Flow Chart (Cooling Only)The following chart are efficient checking procedures for troubleshooting when these fan-coil units, arecouple

Seite 25 - (7) Overall Checking

30Insufficient CoolingHigh Discharge PressureLow Discharge PressureLow DischargePressureMalfunction Of Fan CyclingSystemCondenserAir FlowLow Refrigera

Seite 26

31High Suction PressureLow Suction PressureNoisy OperationHigh SuctionPressureExcessive Fresh Air IntakeEvaporatorAir InletTemperatureInsufficient Duc

Seite 27 - Servicing and maintenance

32No Cooling / HeatingUnit fail to startCheck power supply- voltage- phase- frequencyCheck settings of remote control boxCompressor fails to startChec

Seite 28

33The most common causes of air conditioner failure to “start" are:a) Voltage not within ±10% of rated voltage.b) Power supply interrupted.c) Con

Seite 29 - Troubleshooting

DOP : 0299Americas - 13600 Industrial Park Boulevard, P.O. Box 1551, Minneapolis, MINI 55440 USA (612) 553-5330Asia - Jalan Pengapit 15/19, P.O. Box 7

Seite 30 - No Cooling

3SpecificationsCooling onlyMODEL INDOOR UNIT MCM020D MCM025D MCM030DOUTDOOR UNIT MLC020B MLC025B MMC030A MMC040B MLC040C MMC050B MLC050CNOMINAL kcal/

Seite 31 - Low Discharge Pressure

4Heat PumpMODELINDOOR UNITMCM020DRMCM025DRMCM030DRMCM040DRMCM050DROUTDOOR UNITMLC020BRMLC025BRMLC030CRMLC040CRMLC050CRNOMINAL kcal/h 5,040 6,048 7,56

Seite 32 - Noisy Operation

5Outlines and dimensionsOutlines and dimensionsIndoor UnitModel: MCM - D SERIES(Cooling only and heat pump)MODEL MCM 020D/DR MCM 025D/DR MCM 030D/DR M

Seite 33 - For Heat Pump Models

6Outdoor unitModel: MLC - B SERIESMODEL A B C D E F G H J K L M N P Q RMLC 020B / BR 840 646 330 297 309 626 46 90 64 177 106 408 378 124 492 78.5MLC

Seite 34

7Model : MLC 040/050C, MLC 030/040/050CRCaution Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from bei

Seite 35 - DOP : 0299

8Wiring diagramsWiring diagramsModel : MCM 020/025D - MLC 020/025B

Kommentare zu diesen Handbüchern

Keine Kommentare